Unit vii case study | Environmental science homework help

UNIT VII CASE STUDY

Read the incident scenario, and write a response that is at least three pages in length. Your response must include answers to the questions being asked. All sources used, including the textbook, must be referenced. Paraphrased and/or quoted materials must have accompanying in-text and reference citations in APA format.

Scenario:

You are the Refinery Emergency Response Coordinator for an incident at the SJV Refinery which has been in operation since 1966. The refinery processes 120,000 bbls of crude oil per day, which has a sulfur content of 2.5 percent. The refinery converts crude oil to naptha, light oil, and heavy oils using the Atmospheric/Vacuum Distillation Unit with key equipment such as the following:

·         · naptha, kerosene, gasoline, and diesel hydrotreaters;

·         · isomerization unit;

·         · naptha reformer;

·         · fluid catalytic cracker;

·         · coker;

·         · hydrocracker;

·         · polymerization unit (petrochemical section of the refinery polymerizing olefin gases to produce polyethylene);

·         · sulfur recovery Claus plant (catalytic reactors); and

·         · distillate/gasoline blending tanks.

The refinery was initiating work on a major plant turnaround at the time of the incident to complete required maintenance repairs, mechanical integrity inspections, and modifications to existing equipment. Twenty contractor companies (approximately 150 employees) have been contracted to perform this work under the direction of refinery staff. All of the contractor workers completed the refinery orientation training.

Work for the contractor crews is assigned/scheduled each morning. On the day of the incident, the day-shift (6 am to 6 pm) crew had been tasked with isolating the acid gas feed stream for the Claus unit. Due to other work priorities, the crew did not isolate the line as planned. A shift turnover for the night contractor crew did not happen due to mandatory safety training that delayed their arrival at the worksite. Upon their arrival at the work site, the night crew held a job safety analysis (JSA) review of the scheduled task (line breaking of the acid gas feed line to replace a segment) to be performed and the hazards present. No pressure gauges or monitoring was present to indicate that the acid gas feed line was operational. The crew initiated the line breaking activity (open the line to the atmosphere) at approximately 7:45 pm under self-contained breathing apparatus (SCBA), which almost immediately resulted in the uncontrolled release of acid gas. A nearby ignition source from a welding operation ignited the flammable gas. The following actions were initially taken:

·         · The evacuation alarm was sounded and the refinery emergency response team (ERT) was activated.

·         · The plant manager and the local fire department were notified of the incident.

·         · The incident command was established at the refinery office near the main refinery access gate to the south (this

is the furthest distance within the refinery boundary from the incident location).

·         · The refinery ERT incident commander implemented actions required under the approved refinery emergency

response plan.

·         · The ERT was not able to immediately isolate the acid gas feed pipeline.

·         · The fire department arrived on location and assumed the incident command of the event.

Additional Relevant Information:

·         · The refinery encompasses an area measuring 2000 feet by 1400 feet. The Claus unit is located in the most northern part of the refinery, approximately 1350 feet from the main refinery access gate to the south. The polymerization unit is operating directly adjacent to the Claus unit.

·         · The nearest residential community is located approximately 1000 feet to the northeast of the refinery.

·         · A plastic recycling plant is located along the south fence boundary of the refinery.

BOS 3640, Interactions of Hazardous Materials 3

·         · A major interstate highway runs directly parallel to the plant, approximately 1/4 of a mile directly north of the refinery.

·         · The ambient temperature on the day of the incident was 85° F and the wind was blowing at 7 mph from the southwest to the northeast.

·         · Work crews were scheduled to work 12-hour shifts, 24-hours a day, to complete the refinery turnaround.

·         · Due to the age of the refinery, SJV has implemented a robust mechanical integrity program.

·         · The refinery has a trained ERT that can respond to incidents.

·         · Fixed water monitors are present throughout the refinery to extinguish refinery equipment fires. The refinery ERT

does not fight fires past the incipient stage.

·         · The refinery has received notices of violation (NOVs) from the local air district in the past several years due to gas

and liquid leaks from piping components, such as valves, compressor/pump seals, and for excess sodium dioxide

(SO2) emissions related with their sulfur plant.

·         · Due to historical discharges of organic compounds, groundwater monitoring wells are present down gradient of

the facility. Groundwater underlying the plant has historically been encountered at 30 feet below ground surface.

·         · Hydrogen sulfide is present in the acid gas feed to the Claus plant. The H2S concentration of the acid gas feed is

approximately 70 percent by volume. H2S and sulfur dioxide (SO2) have the following physical properties:

Physical Property

H2S

SO2

Specific Gravity at 68oF (20oC)

1.54

1.4

Vapor Density (Air=1)

1.18

2.22

Flashpoint

-116oF (-82.4oC)

Not Applicable

Autoignition Point

500oF (260oC)

Not Applicable

Lower Explosive Limit

4.3%

Not Applicable

Upper Explosive Limit

46%

Not Applicable

IDLH

100 ppm

100 ppm

Questions:

1.      Discuss the hazards posed by the interaction of the hazardous materials present at the refinery and adjacent facilities, including the resulting by-products of the incident fire and acid gas release.

2.      As the lead refinery representative on the unified incident command (UIC), what actions should be taken by the UIC to respond to this incident (please consider all receptors).

3.      If the polymerization unit is engulfed in the fire, how will this affect your response?

 

4.      All emergency responders participated in the post-incident critique. What corrective actions should be implemented by the refinery to prevent the reoccurrence of this incident?

Calculate the price
Make an order in advance and get the best price
Pages (550 words)
$0.00
*Price with a welcome 15% discount applied.
Pro tip: If you want to save more money and pay the lowest price, you need to set a more extended deadline.
We know how difficult it is to be a student these days. That's why our prices are one of the most affordable on the market, and there are no hidden fees.

Instead, we offer bonuses, discounts, and free services to make your experience outstanding.
How it works
Receive a 100% original paper that will pass Turnitin from a top essay writing service
step 1
Upload your instructions
Fill out the order form and provide paper details. You can even attach screenshots or add additional instructions later. If something is not clear or missing, the writer will contact you for clarification.
Pro service tips
How to get the most out of your experience with Australia Assessments
One writer throughout the entire course
If you like the writer, you can hire them again. Just copy & paste their ID on the order form ("Preferred Writer's ID" field). This way, your vocabulary will be uniform, and the writer will be aware of your needs.
The same paper from different writers
You can order essay or any other work from two different writers to choose the best one or give another version to a friend. This can be done through the add-on "Same paper from another writer."
Copy of sources used by the writer
Our college essay writers work with ScienceDirect and other databases. They can send you articles or materials used in PDF or through screenshots. Just tick the "Copy of sources" field on the order form.
Testimonials
See why 20k+ students have chosen us as their sole writing assistance provider
Check out the latest reviews and opinions submitted by real customers worldwide and make an informed decision.
Military
Excellent job.
Customer 456821, May 11th, 2022
Military
good job
Customer 456821, May 18th, 2022
SEO
I'm very pleased with what I received. Thank you for following instructions and for going an extra mile and delivering well researched and well-written content. Thank you.
Customer 463869, April 12th, 2023
Business and administrative studies
Thank you for the corrections. This is what I expected my paper to be.
Customer 460555, November 22nd, 2021
Healthcare & Medical
Instructions followed quite well.
Customer 452441, April 13th, 2022
Business Studies
Great job!
Customer 462533, April 10th, 2022
History
Outstanding clarity.
Customer 456665, April 21st, 2022
Religious studies
Excellent content and structure.
Customer 462681, April 24th, 2022
Film & Theater studies
Fairly articulated.
Customer 462929, May 4th, 2022
Environmental studies and Forestry
Good work.
Customer 458115, May 29th, 2022
Military
good job
Customer 456821, October 24th, 2022
Social Sciences
None
Customer 453751, June 14th, 2020
11,595
Customer reviews in total
96%
Current satisfaction rate
3 pages
Average paper length
37%
Customers referred by a friend
OUR GIFT TO YOU
15% OFF your first order
Use a coupon FIRST15 and enjoy expert help with any task at the most affordable price.
Claim my 15% OFF Order in Chat